Fire Finder

Showing 3 products

Dyn-Optics Fire Finder II Model 955 with Hard Case

FireFinder02

Specifications:• Sensitivity - Responds to 200 degrees F hot area one   foot square at  20 feet.• Heat Indication - An audible alarm will sound when the   FIRE FINDER II  is pointed at a hot spot. The pitch of the alarm  is proportional to the  temperature - the higher the   temperature, the higher the pitch. • Sensitivity to sunlight - Detects a cigarette on a hot side   walk in full sunlight. • Response Time - Less than 0.1 second to full audible alarm.• Construction - Durable water resistant aluminum housing. • No plastic components. • Operation - Simple on-off switch. • Built-in self-test - Initiated when unit is turned on to assure   the operator unit is  functioning properly. • Power - Four 1.5 volt AA batteries that can easily be   replaced by removing rear cover. Uses; • Verifies fire is extinguished • Seeks out residual embers in full sunlight • Detects transparent chemical fire during haz-mat   incidences • Finds hot spots • Locates overheated ballasts in fluorescent lights • Identifies overheated machinery • Spots hot wiring • Prevents rekindle by locating residual embers during   overhaul The Fire Finder II incorporates two new features:1) the HELP WANTED ALARM activated by the firefighter and 2) a BATTERIES NEED CHANGING ALARM. In addition, the Fire Finder II Model 955 has been tested and certified intrinsically safe to be used in explosive environments,in conformity with MIL-STD-202F, method 109B. Dyn-Optics has a patent on the Fire Finder. Any other device representing to be a Fire Finder or heat sensor may be counterfeit or infringe on the patent. Dimensions 10.25" L x 3" DIncludes:• Hard Padded Case• Soft Case• Instructions• Batteries (2) 9-Volts

Fire Finder II Model 955

FireFinder01

Model 955 Fire Finder Professional is easy to operate and designed to give reliable performance time after time.

The Model 955 Fire Finder Professional is easy to operate and designed to give reliable performance time after time. Held like a flashlight and waved around a suspected area, the Fire Finder Professional quickly finds hot spots and emits a loud alarm instantly alerting the operator. The pitch of the alarm increases as the Fire Finder is pointed closer to the hot spot allowing the firefighter to quickly locate heat sources without taking his eyes off the area being investigated. Specifications: Sensitivity - Responds to 200 degrees F hot area one foot square at  20 feet Heat Indication - An audible alarm will sound when the FIRE FINDER II is pointed at a hot spot. The pitch of the alarm is proportional to the  temperature - the higher the temperature, the higher the pitch Sensitivity to sunlight - Detects a cigarette on a hot side walk in full sunlight  Response Time - Less than 0.1 second to full audible alarm Construction - Durable water resistant aluminium housing  No plastic components Operation - Simple on-off switch Built-in self-test - Initiated when unit is turned on to assure the operator unit is functioning properly Power - Four 1.5 volt AA batteries that can easily be replaced by removing rear cover Uses: Verifies fire is extinguished Seeks out residual embers in full sunlight Detects transparent chemical fire during haz-mat incidences Finds hot spots Locates overheated ballasts in fluorescent lights Identifies overheated machinery Spots hot wiring Prevents rekindle by locating residual embers during overhaul Dimensions 10.25" L x 3" D Includes; Dyn-Optics Model 955 Fire Finder Professional Thermal Scanner Cordura Carrying Pouch Reflective Wrist Lanyard Operations Manual

Model 955L Red Hawk Thermal Scanner

FireFinder03

The Model 955L RedHawk™ Thermal Scanner is the latest and most advanced addition to the time-proven line of thermal scanners manufactured by Dyn-Optics that have been aiding fire fighters and smoke jumpers for years. The RedHawk™ includes a bright Class II red aiming laser for pin-point location of hot spots inside structures, on walls, ceilings and other structural features. The RedHawk™ uses a loud audible alarm to alert the presence of a hot spot and unlike a TIC, it does not need a viewfinder to  distract the attention of the firefighter from the scene at hand. For outdoor use (i.e.. wildland),  SmartSight™ Technology allows the RedHawk™ maintain maximum sensitivity even in full sunlight. The RedHawk™ can detect heat sources as small as a lit cigarette on an asphalt roadway in broad sunlight. Unlike thermal imagers and IR thermometer, the RedHawk Thermal Scanner is unaffected by sunlight giving it unsurpassed performance in outdoor applications. Specifications: Quickly Finds Hot Spots Prevents Call Backs Sees Through Glass Works in Full Sunlight SmartSight™ Technology Lightweight (less than 1 lb) Finish Mop Up in 1/5th Time Saves Time & Money Unique Patented Design SmartSight™ Technology Faster, Reliable Hot Spot Detection Operates Through Glass Bright Class II Red Laser Uses Standard AA Batteries Lightweight, Easy to Use Rugged Anodised Aluminium Housing

    Showing 1–3 of 3 results