Specifications:
• Sensitivity - Responds to 200 degrees F hot area one
foot square at 20 feet.
• Heat Indication - An audible alarm will sound when the
FIRE FINDER II is pointed at a hot spot. The pitch of the alarm
is proportional to the temperature - the higher the
temperature, the higher the pitch.
• Sensitivity to sunlight - Detects a cigarette on a hot side
walk in full sunlight.
• Response Time - Less than 0.1 second to full audible alarm.
• Construction - Durable water resistant aluminum housing.
• No plastic components.
• Operation - Simple on-off switch.
• Built-in self-test - Initiated when unit is turned on to assure
the operator unit is functioning properly.
• Power - Four 1.5 volt AA batteries that can easily be
replaced by removing rear cover.
Uses;
• Verifies fire is extinguished
• Seeks out residual embers in full sunlight
• Detects transparent chemical fire during haz-mat
incidences
• Finds hot spots
• Locates overheated ballasts in fluorescent lights
• Identifies overheated machinery
• Spots hot wiring
• Prevents rekindle by locating residual embers during
overhaul
The Fire Finder II incorporates two new features:
1) the HELP WANTED ALARM activated by the firefighter and
2) a BATTERIES NEED CHANGING ALARM.
In addition, the Fire Finder II Model 955 has been tested and
certified intrinsically safe to be used in explosive environments,
in conformity with MIL-STD-202F, method 109B.
Dyn-Optics has a patent on the Fire Finder. Any other device
representing to be a Fire Finder or heat sensor may be
counterfeit or infringe on the patent.
Dimensions 10.25" L x 3" D
Includes:
• Hard Padded Case
• Soft Case
• Instructions
• Batteries (2) 9-Volts